REG compressed air pressure reducing valve, SYNTESI® series

Additional information

Maximum operating temperature [°C]

50

Minimum operating temperature [°C]

-10

Standard length [m]

10

REG pressure reducing valve, SYNTESI® series, with end connections 1/8″ to 1″, is used for regulating operating pressure and maintaining it at a constant level, ensuring proper operation in the connected installation, regardless of the changing consumption of the medium. The valve uses a shaped diaphragm instead of a flat diaphragm, which provides higher nominal flow values due to greater diaphragm travel, as well as increased sensitivity and response speed to setting changes by reducing static and kinetic friction of components and greater accuracy in maintaining the set output pressure with changes in flow and supply pressure. In the event of an increase in output pressure above the set value, the diaphragm opens the drain valve and vents the reducer until the pressure value matches the setting. The push-lock mechanism allows the knob to be locked in any position by pressing it. The locking plate enables the installation of a padlock to prevent unauthorized changes to the output pressure setting. Additional connections at the front and back can be used to connect a pressure gauge, pneumatic-electric relay, or plug couplings. Air drawn from these connections is reduced. Size: SY1, SY2. Output pressure range: 0 to 2, 0 to 4, 0 to 8, 0 to 12 bar. Supply pressure: up to 15 bar, depending on size. Operating temperature: from -10°C to +50°C. Connection: BSP thread 1/8″ to 1″. Additional connection for pressure gauge or couplings: BSP thread 1/8″ for size SY1, BSP thread 1/4″ for size SY2. Flow: 1200 l/min – 1/8″, 2800 l/min – 1/4″, 3350 l/min – 3/8″ (SY1), 5300 l/min – 3/8″ (SY2), 7400 l/min – 1/2″, 7600 l/min – 3/4″ and 1″ (at an inlet pressure of 6 bar Δp = 1 bar).

List of product variants

Article numberProduct variant nameDNBARAvailabilityPriceQuantityActionsCatalogue
MW-5611R101REG SY1 1/8 02 pressure reducing valve--In stock
Enquiry
MW-5611R121REG SY1 1/8 04 pressure reducing valve--In stock
Enquiry
MW-5611R141REG SY1 1/8 08 pressure reducing valve--In stock
Enquiry
MW-5611R161REG SY1 1/8 012 pressure reducing valve--In stock
Enquiry
MW-5612R102REG SY1 1/4 02 pressure reducing valve--In stock
Enquiry
MW-5612R122REG SY1 1/4 04 pressure reducing valve--In stock
Enquiry
MW-5612R142REG SY1 1/4 08 pressure reducing valve--In stock
Enquiry
MW-5612R162REG SY1 1/4 012 pressure reducing valve--In stock
Enquiry
MW-5613R103REG SY1 3/8 02 pressure reducing valve--In stock
Enquiry
MW-5613R123REG SY1 3/8 04 pressure reducing valve--In stock
Enquiry
MW-5613R143REG SY1 3/8 08 pressure reducing valve--In stock
Enquiry
MW-5613R163REG SY1 3/8 012 pressure reducing valve--In stock
Enquiry
MW-5623R103REG SY2 3/8 02 pressure reducing valve--In stock
Enquiry
MW-5623R143REG SY2 3/8 08 pressure reducing valve--In stock
Enquiry
MW-5623R163REG SY2 3/8 012 pressure reducing valve--In stock
Enquiry
MW-5624R104REG SY2 1/2 02 pressure reducing valve--In stock
Enquiry
MW-5624R124REG SY2 1/2 04 pressure reducing valve--In stock
Enquiry
MW-5624R144REG SY2 1/2 08 pressure reducing valve--In stock
Enquiry
MW-5624R164REG SY2 1/2 012 pressure reducing valve--In stock
Enquiry
MW-5625R105REG SY2 3/4 02 pressure reducing valve--In stock
Enquiry
MW-5625R125REG SY2 3/4 04 pressure reducing valve--In stock
Enquiry
MW-5625R145REG SY2 3/4 08 pressure reducing valve--In stock
Enquiry
MW-5625R165REG SY2 3/4 012 pressure reducing valve--In stock
Enquiry
MW-5626R106REG SY2 1 02 pressure reducing valve--In stock
Enquiry
MW-5626R126REG SY2 1 04 pressure reducing valve--In stock
Enquiry
MW-5626R146REG SY2 1 08 pressure reducing valve--In stock
Enquiry
MW-5626R166REG SY2 1 012 pressure reducing valve--In stock
Enquiry

Do you need a larger quantity of products or a bespoke quote?

REG pressure reducing valve, SYNTESI® series, with end connections 1/8″ to 1″, is used for regulating operating pressure and maintaining it at a constant level, ensuring proper operation in the connected installation, regardless of the changing consumption of the medium. The valve uses a shaped diaphragm instead of a flat diaphragm, which provides higher nominal flow values due to greater diaphragm travel, as well as increased sensitivity and response speed to setting changes by reducing static and kinetic friction of components and greater accuracy in maintaining the set output pressure with changes in flow and supply pressure. In the event of an increase in output pressure above the set value, the diaphragm opens the drain valve and vents the reducer until the pressure value matches the setting. The push-lock mechanism allows the knob to be locked in any position by pressing it. The locking plate enables the installation of a padlock to prevent unauthorized changes to the output pressure setting. Additional connections at the front and back can be used to connect a pressure gauge, pneumatic-electric relay, or plug couplings. Air drawn from these connections is reduced. Size: SY1, SY2. Output pressure range: 0 to 2, 0 to 4, 0 to 8, 0 to 12 bar. Supply pressure: up to 15 bar, depending on size. Operating temperature: from -10°C to +50°C. Connection: BSP thread 1/8″ to 1″. Additional connection for pressure gauge or couplings: BSP thread 1/8″ for size SY1, BSP thread 1/4″ for size SY2. Flow: 1200 l/min – 1/8″, 2800 l/min – 1/4″, 3350 l/min – 3/8″ (SY1), 5300 l/min – 3/8″ (SY2), 7400 l/min – 1/2″, 7600 l/min – 3/4″ and 1″ (at an inlet pressure of 6 bar Δp = 1 bar).

Additional information

Maximum operating temperature [°C]

50

Minimum operating temperature [°C]

-10

Standard length [m]

10

Do you need a larger quantity of products or a bespoke quote?

Sales Network
Check

Inquiry
Send

Related Products

If you need help choosing a product or haven’t found the right one?